مقاله همراه با ترجمه با موضوع ساختار سیستم مدیریت ارتباط با مشتری در داده کاوی

 مقاله همراه با ترجمه با موضوع ساختار سیستم مدیریت ارتباط با مشتری در داده کاوی


S.Thiripura Sundari, Dr.A.Padmapriya / International Journal of Engineering Research andApplications (IJERA) ISSN: 2248-9622 www.ijera.comVol. 2, Issue 5, September- October 2012, pp.107-111107 | P a g eStructure Of Customer Relationship Management Systems InData MiningS.Thiripura Sundari*, Dr.A.Padmapriya***(Department of Computer Science and Engineering, Alagappa University, Karaikudi-630 003** (Department of Computer Science and Engineering, Alagappa University, Karaikudi-630 003ABSTRACTAs a young research field, data mininghas made broad and significant progress. Today,data mining is used in a vast array of areas, andnumerous commercial data mining systems areavailable. On the basis of detailed analysis of theexisting CRM structure, a new design scheme ofcustomer relationship management systems basedon data mining is presented and the design detailsof which are illustrated in detail.

خرید و دانلود  مقاله همراه با ترجمه با موضوع ساختار سیستم مدیریت ارتباط با مشتری در داده کاوی


مقاله تحلیل فرکانس شبکه با موضوع نفوذ توان باد زیاد

 مقاله تحلیل فرکانس شبکه با موضوع نفوذ توان باد زیاد


عنوان انگلیسی:
Grid Frequency Analysis with the Issue of High Wind Power Penetrationعنوان فارسی:
تحلیل فرکانس شبکه با موضوع نفوذ توان باد زیاد

ناشر :IEEE-International Conference on Electrical Information and Communication Technology

سال انتشار:2013

تعداد صفحات ترجمه: 19 بصورت word

تعداد صفحات انگلیسی:6 بصورت pdf

Abstract
As wind turbine output is proportional to the cube of wind speed, the wind turbine generator output fluctuates due to random variations of wind speed. Hence, if the power capacity of wind power generator becomes large, wind power generator output can have an influence on the power system frequency. Therefore, this study investigates the influence of the ratio of wind capacity to the power system capacity, on the power system frequency. To do this, a 100[MVA] thermal synchronous generator (SG) is considered and the total capacity of wind power induction generator (IG) increases as 3[MVA], 5[MVA] and 10[MVA] connected to the line. It is seen that the system frequency fluctuation is more severe for 10% capacity of wind power penetration. Again, a hydro generator to the same capacity that of the thermal generator of 100[MVA] is considered and IG capacity increases as before. In this case, it is seen that the system frequency fluctuation is more severe for 10% capacity of wind power. However, SGs total capacity of 100[MVA] is considered combined with 50[MVA] thermal generator and 50[MVA] hydro generator and IG capacity increases as before. In this case, it is also seen that the system frequency fluctuation is more severe for 10% of total wind power capacity. For this reason , as the wind power penetration increases rapidly nowadays for its clean, non-polluting and renewable energy, this study will be helpful for taking preventive measures for the power grid operators to improve the stability and quality of electric power. Considering these point of view, this study plays a vital role for power system applications


چکیده:
با توجه به اینکه خروجی توربین بادی متناسب با توان سوم سرعت باد است بنابراین خروجی ژنراتور توربین بادی بعلت تغییرات تصادفی سرعت باد تغییر میکند و از آنجایی که اگر توان ژنراتور بادی زیاد شود خروجی ژنراتور بادی می تواند بر روی فرکانس سیستم قدرت تاثیر بگذارد بنابراین این مقاله تاثیر نسبت ظرفیت باد به ظرفیت سیستم قدرت بر روی فرکانس سیستم قدرت را بررسی میکند.برای انجام این کار یک ژنراتور سنکرون حرارتی 100 مگا ولت آمپری در نظر گرفته میشود و کل ظرفیت ژنراتور القایی توان بادی متصل به شبکه بصورت5،3و 10 مگا ولت آمپر افزایش پیدا میکند.مشاهده میشود که برای نفوذ ظرفیت توان بادی 10 درصد توان کل، تغییرات فرکانس سیستم خیلی زیاد است و بار دیگر یک ژنراتور آبی با همان ظرفیت 100 مگا ولت آمپر ژنراتور حرارتی، در نظر گرفته میشود و طرفیت ژنراتور القایی مانند قبل افزایش پیدا میکند مشاهده میشود که برای 10درصد ظرفیت توان کل،تغییرات فرکانس خیلی زیاد است . با وجود این فرض میشود که کل ظرفیت 100 مگا ولت آمپری SGs از ترکیب یک ظرفیت 50 مگا ولت آمپری ژنراتور حرارتی ویک ظرفیت 50مگا ولت آمپری ژنراتور آبی بدست می آید و ظرفیت ژنراتور القایی مانند گذشته افزایش پیدا میکند.در این حالت مشاهده میشود که برای 10درصد کل ظرفیت توان ، تغییرات فرکانس سیستم خیلی بیشتراست.به این دلیل همانطوری که امروزه نفود توان باد بخاطر پاک بودن،فاقد آلودگی بودن و تجدید پذیر بودن به سرعت افزایش پیدا میکند این مطالعه نیز بمنظوراقدامات پیشگیرانه اپراتورهای شبکه قدرت برای بهبود پایداری و کیفت توان الکتریکی مفید خواهد بود.با توجه به این نقطه نظر این بررسی یک نقش مهم برای برنامه های کاربردی سیستم قدرت دارد.


خرید و دانلود  مقاله تحلیل فرکانس شبکه با موضوع نفوذ توان باد زیاد